Product Replacement Program

In April 2013, tests conducted by the Company revealed that one of its suppliers had been using a non-conforming part in power supplies for certain models of Astro-Med’s Test & Measurement printers. No malfunctions have been reported by customers as a result of the non-conforming material.

Upon identifying this issue, Astro-Med immediately suspended production of the printers, notified all customers and contacted the supplier who confirmed the problem. Astro-Med is continuing to work with its customers to replace the non-conforming material on existing printers with conforming material. The estimated costs associated with the replacement program were $672,000, which was based upon the number of printers shipped during the period the non-conforming material was used. Those estimated costs were recognized and recorded as a reserve in the first quarter of fiscal 2014. As of May 2, 2015, the Company had expended $338,000 in replacement costs which have been charged against this reserve. The remaining reserve amount of $334,000 is included in Other Accrued Expenses in the accompanying condensed consolidated balance sheet dated May 2, 2015.

Astro-Med is currently receiving power supplies with compliant parts and has resumed printer production and shipments to customers.

Since the supplier deviated from the agreed upon specifications for the power supply while providing certificates of conformance to the original specifications, in January 2014, Astro-Med received a non-refundable $450,000 settlement from the supplier for recovery of the costs and expense associated with this issue. In addition to this cash settlement, the Company is receiving lower product prices from the supplier through fiscal 2017.