-----BEGIN PRIVACY-ENHANCED MESSAGE----- Proc-Type: 2001,MIC-CLEAR Originator-Name: webmaster@www.sec.gov Originator-Key-Asymmetric: MFgwCgYEVQgBAQICAf8DSgAwRwJAW2sNKK9AVtBzYZmr6aGjlWyK3XmZv3dTINen TWSM7vrzLADbmYQaionwg5sDW3P6oaM5D3tdezXMm7z1T+B+twIDAQAB MIC-Info: RSA-MD5,RSA, JUFDUkLUGgcs5uYT/8f/Slo1tAFBH7eRBX6TZoJaf7olNe/NvXq+X8iawfms/z74 kSyn98znVdulS89O2CTF1w== 0001299933-05-006837.txt : 20051227 0001299933-05-006837.hdr.sgml : 20051226 20051223193228 ACCESSION NUMBER: 0001299933-05-006837 CONFORMED SUBMISSION TYPE: 8-K PUBLIC DOCUMENT COUNT: 3 CONFORMED PERIOD OF REPORT: 20051222 ITEM INFORMATION: Regulation FD Disclosure ITEM INFORMATION: Other Events FILED AS OF DATE: 20051227 DATE AS OF CHANGE: 20051223 FILER: COMPANY DATA: COMPANY CONFORMED NAME: STAAR SURGICAL CO CENTRAL INDEX KEY: 0000718937 STANDARD INDUSTRIAL CLASSIFICATION: OPHTHALMIC GOODS [3851] IRS NUMBER: 953797439 STATE OF INCORPORATION: DE FISCAL YEAR END: 0101 FILING VALUES: FORM TYPE: 8-K SEC ACT: 1934 Act SEC FILE NUMBER: 000-11634 FILM NUMBER: 051286046 BUSINESS ADDRESS: STREET 1: 1911 WALKER AVE CITY: MONROVIA STATE: CA ZIP: 91016 BUSINESS PHONE: 6263037902 MAIL ADDRESS: STREET 1: 1911 WALKER AVE CITY: MONROVIA STATE: CA ZIP: 91016 FORMER COMPANY: FORMER CONFORMED NAME: STAAR SURGICAL COMPANY DATE OF NAME CHANGE: 19920703 8-K 1 htm_9196.htm LIVE FILING STAAR Surgical Company (Form: 8-K)  

 


UNITED STATES
SECURITIES AND EXCHANGE COMMISSION

WASHINGTON, D.C. 20549

FORM 8-K

CURRENT REPORT

Pursuant to Section 13 or 15(d) of the Securities Exchange Act of 1934

     
Date of Report (Date of Earliest Event Reported):   December 22, 2005

STAAR Surgical Company
__________________________________________
(Exact name of registrant as specified in its charter)

     
Delaware 0-11634 95-3797439
_____________________
(State or other jurisdiction
_____________
(Commission
______________
(I.R.S. Employer
of incorporation) File Number) Identification No.)
      
1911 Walker Ave, Monrovia, California   91016
_________________________________
(Address of principal executive offices)
  ___________
(Zip Code)
     
Registrant’s telephone number, including area code:   626-303-7902

Not Applicable
______________________________________________
Former name or former address, if changed since last report

 

Check the appropriate box below if the Form 8-K filing is intended to simultaneously satisfy the filing obligation of the registrant under any of the following provisions:

[  ]  Written communications pursuant to Rule 425 under the Securities Act (17 CFR 230.425)
[  ]  Soliciting material pursuant to Rule 14a-12 under the Exchange Act (17 CFR 240.14a-12)
[  ]  Pre-commencement communications pursuant to Rule 14d-2(b) under the Exchange Act (17 CFR 240.14d-2(b))
[  ]  Pre-commencement communications pursuant to Rule 13e-4(c) under the Exchange Act (17 CFR 240.13e-4(c))


Item 7.01 Regulation FD Disclosure.

On December 23, 2005, STAAR Surgical Company (the "Company") published a press release announcing that it had received a letter from the Office of Device Evaluation of the U.S. Food and Drug Administration (the "FDA") on December 22, 2005 (the "Approval Letter") approving the Company’s pre-market approval application ("PMA") for the STAAR Myopic VISIAN ICL™. A copy of the press release is furnished as Exhibit 99.1 hereto.





Item 8.01 Other Events.

The Company received the Approval Letter regarding the STAAR Myopic VISIAN ICL™ from the FDA on December 22, 2005.

The ICL is a refractive phakic implant intended for placement in the posterior chamber of the eye. The approved models are indicated for the correction of myopia in adults with myopia ranging from -3.0 to less than or equal to -15.0 diopters with astigmatism less than or equal to 2.5 diopters at the spectacle plane, and the reduction of myopia in adults with myopia ranging from greater than -15.0 to -20.0 diopters with astigmatism less than or equal to 2.5 diopters at the spectacle plane, in patients 21-45 years of age with anterior chamber depth (ACD) of 3.00 mm or greater, and a stable refractive history within 0.5 diopters for one year prior to implantation.

The foregoing summary is qualified in its entirety by reference to the complete text of the Approval Letter, a copy of which is attached to this report as Exhibit 99.2, and which is incorporated herein by this ref erence.






SIGNATURES

Pursuant to the requirements of the Securities Exchange Act of 1934, the registrant has duly caused this report to be signed on its behalf by the undersigned hereunto duly authorized.

         
    STAAR Surgical Company
          
December 23, 2005   By:   David Bailey
       
        Name: David Bailey
        Title: President and Chief Executive Officer


Exhibit Index


     
Exhibit No.   Description

 
99.1
  Press release dated December 23, 2005.
99.2
  Letter from U.S. Food and Drug Administration dated December 22, 2004 regarding approval of Premarket Approval Application for the STAAR VISIAN(TM) ICL.
EX-99.1 2 exhibit1.htm EX-99.1 EX-99.1

STAAR SURGICAL’S VISIAN ICL™ RECEIVES FDA APPROVAL

Company Expects to Begin Product Shipments Within Six Weeks

MONROVIA, CA., December 23, 2005 – STAAR Surgical Company (Nasdaq:STAA) today reported that the U.S. Food and Drug Administration (FDA) has approved the Company’s Myopic VISIAN ICL™ for use in the correction of myopia in adults.

Made of STAAR’s proprietary, highly biocompatible Collamer® material, the ICL (an abbreviation for Implantable Collamer Lens) is the only minimally invasive foldable lens of its kind approved for the U.S. commercial market. As a result of the unique foldable design, the ICL procedure allows an incision up to 50% smaller than competing technology, and its placement in the eye behind the iris provides a more aesthetically pleasing outcome. In addition to the U.S., the ICL is also approved for sale in 41 countries, including the European Union and has successfully been implanted in more than 40,000 eyes worldwide.

The Company expects to begin shipping the VISIAN ICL to trained doctors in six to eight weeks. In addition, STAAR plans to showcase the new product through training courses and other educational sessions at key upcoming industry symposia including the Royal Hawaiian Eye Meeting and the American Society of Cataract and Refractive Surgery meeting.

“The ICL remains our most significant opportunity for profitable growth going forward and receipt of FDA approval represents a critical milestone,” said David Bailey, President and CEO of STAAR Surgical. “Throughout the approval process, doctors’ interest in our state-of-the-art lens has continued to build, driven by superior clinical outcomes, the stability and safety of the procedure and the high patient satisfaction rate. We believe the ICL offers patients and their doctors opportunities to achieve higher quality visual outcomes compared with competing technology and this characteristic will be an important growth driver of the refractive phakic implant market. Based upon these dynamics and the success of the ICL in the international markets, we believe that we are well positioned to begin building a strong franchise in the U.S.

“We continue to plan for a controlled commercial launch and believe that the investments we made in our marketing programs two years ago have allowed us to build the infrastructure necessary to be successful,” continued Mr. Bailey. “As we have done internationally, we will guide doctors through our training and certification process, which includes proctoring the first five surgeries. Currently, we have more than 860 surgeons who have completed the first phase of training and are ready to be proctored by the five application specialists that we have on staff. Once the doctors have successfully completed the surgeries, they will become certified and will be eligible to order additional VISIAN ICL lenses without a proctor. We believe that this process, which focuses on correct technique, will support high quality clinical outcomes and better ensure proper use of the lens.”

The VISIAN ICL is a refractive phakic implant intended for placement in the posterior chamber of the eye. The approved models are indicated for the correction of myopia in adults with myopia ranging from -3.0 to less than or equal to -15.0 diopters with astigmatism less than or equal to 2.5 diopters at the spectacle plane, and the reduction of myopia in adults with myopia ranging from greater than -15.0 to -20.0 diopters with astigmatism less than or equal to 2.5 diopters at the spectacle plane, in patients 21 to 45 years of age with anterior chamber depth (ACD) 3.00 mm or greater, and a stable refractive history within 0.5 diopters for one year prior to implantation.

About STAAR Surgical

STAAR Surgical is a leader in the development, manufacture and marketing of minimally invasive ophthalmic products employing proprietary technologies. STAAR’s products are used by ophthalmic surgeons and include the revolutionary VISIAN ICL™ as well as innovative products designed to improve patient outcomes for cataracts and glaucoma. STAAR’s ICL has received CE Marking, is approved for sale in 41 countries and has been implanted in more than 40,000 eyes worldwide.

Safe Harbor

All statements in this press release that are not statements of historical fact are forward-looking statements, including any statements regarding expectations for success of the ICL in U.S. or international markets, projections of sales, profitability or earnings, revenue, cash or other financial items, any statements of the plans, strategies, and objectives of management for future operations, statements of belief and any statements of assumptions underlying any of the foregoing. These statements are based on expectations and assumptions as of the date of this press release and are subject to numerous risks and uncertainties, which could cause actual results to differ materially from those described in the forward-looking statements. The risks and uncertainties include our limited capital resources and limited access to financing, our ability to overcome negative publicity resulting from warning letters and other correspondence from the FDA Office of Compliance, the willingness of surgeons and patients to adopt a new product and procedure, and our ability to successfully launch and market the ICL in the U.S. while overcoming the foregoing challenges. Our ability to capitalize on the opportunity presented by the ICL approval depends on our overall financial condition, which can be adversely affected by our ability to implement our cost savings strategies and realize our expected savings, our ability to reverse the decline in domestic sales of intraocular lenses (“IOLs”), our ability to maintain or enhance our existing product sales and gross profit margin and reduce compliance expenditures, the rapid pace of technological change in the ophthalmic industry, our ability to compete with much larger ophthalmic companies, general domestic and international economic conditions, and other factors beyond our control, including those detailed from time to time in our reports filed with the Securities and Exchange Commission. STAAR assumes no obligation to update these forward-looking statements to reflect future events or actual outcomes and does not intend to do so.

     
CONTACT:
  Investors Media
EVC Group EVC Group
Douglas Sherk, 415-896-6820Steve DiMattia, 646-277-8706
Jennifer Beugelmans, 415-896-6820
 
   

EX-99.2 3 exhibit2.htm EX-99.2 EX-99.2

Department of Health & Human Services

Public Health Service
9200 Corporate Boulevard
Rockville MD 20850

Dec 22 2005

Helene Lamielle, M. D.
Vice President of Scientific Affairs
STAAR Surgical Company
1911 Walker Avenue
Monrovia, CA 91016

     
Re:
  P030016
Visian ICL™ (Implantable Collamer Lens)
Models: MICL12.1, MICL12.6, MlCL13.2, and MICL13.7

      Filed: May 8, 2003

      Amended: May 29, July 8, 10, and 15, August 18, September 3, 4, 11, 22 and 25,

      2003, January 26, August 19, and December 14, 2004, February 1, June 1 and 2,

      July 19, and 27, December 8, 19 and 20, 2005

      Procode: MTA

Dear Dr. Lamielle:

The Center for Devices and Radiological Health (CDRH) of the Food and Drug Administration (FDA) has completed its review of your premarket approval application (PMA) for the Visian ICL™ (Implantable Collamer Lens) — Models: MICL 12.1, MICL12.6, MICL13.2, and MICL13.7.This device is indicated for:

    the correction of myopia in adults with myopia ranging from -3.0 diopters to =- 15.0 diopters with less than or equal to 2.5 diopters of astigmatism at the spectacle plane;

    the reduction of myopia in adults with myopia ranging from greater than -15.0 diopters to -20.0 diopters with less than or equal to 2.5 diopters of astigmatism at the spectacle plane; and,

    patients 21-45 years of age with an anterior chamber depth (ACD) 3.00 mm or greater, and a stable refractive history within 0.5 diopter for 1 year prior to implantation.

We are pleased to inform you that the PMA is approved. You may begin commercial distribution of the device in accordance with the conditions described below and in the “Conditions of Approval” (enclosed).

The sale, distribution, and use of this device are restricted to prescription use in accordance with 21 CFR 80 1.109 within the meaning of section 520(e) of the Federal Food, Drug, and Cosmetic Act (the act) under the authority of section 515(d)(l)(B)(ii) of the act. FDA has also determined that, to ensure the safe and effective use of the device,

1

Page 2 — Helene Lamielle, M. D.

the device is further restricted within the meaning of section 520(e) under the authority of section 515(d)(l)(B)(ii), (1) insofar as the labeling specify the requirements that apply to the training of practitioners who may use the device as approved in this order and (2) insofar as the sale, distribution, and use must not violate sections 502(q) and (r) of the act.

In addition to the postapproval requirements outlined in the enclosure, you have agreed to provide data in annual postapproval reports from the following:

  1.   continued post-operative follow-up of the PMA cohort’s corneal endothelial cell loss out to five years and provide yearly reports to assess long term safety.

  2.   a 5 year postapproval study of the adverse events as per the protocol outlined in Amendment 18. The study will entail enrollment of 5,000 patients within the United States with the goal of obtaining 5 year follow-up on 2000 patients to collect safety information and estimate the safety event rates for the ICL market in contrast to the well-controlled clinical study environment. The following events/complications will be assessed: cataract formation, corneal decompensation, persistent elevated intraocular pressure (more than 3 months) requiring medication or surgical intervention, retinal detachment, chronic uveitis and secondary surgical interventions (e.g. , lens exchange, lens explantation, ICL repositioning).

  3.   a pre- and post-operative axial length measurement sub-study as outlined in Amendment 18 to determine whether the ICL effects this measurement.

Additionally, at the completion of the postapproval studies, you must submit the clinical data and update your labelling accordingly via a PMA supplement.

Expiration dating for this device has been established and approved at 24 months. The STAAR Myopic Visian ICL™ should be stored at room temperature/ambient (Do not freeze or expose to temperatures above 40°C (104°F))

CDRH does not evaluate information related to contract liability warranties, however you should be aware that any such warranty statements must be truthful, accurate, and not misleading, and must be consistent with applicable Federal and State laws.

CDRH will notify the public of its decision to approve your PMA by making available a summary of the safety and effectiveness data upon which the approval is based. The information can be found on the FDA CDRH Internet HomePage located at http://www.fda.gov/crdrh/pmagage.html. Written requests for this information can also be made to the Dockets Management Branch, (HFA-305), Food and Drug Administration, 5630 Fishers Lane, Rm. 1061, Rockville, MD 20852.The written request should include the PMA number or docket number. Within 30 days from the date that this information is placed on the Internet, any interested person may seek review of this decision by requesting an opportunity for administrative review, either through a hearing or review by

2

Page 3 — Helene Lamielle, M.D.

an independent advisory committee, under section 515(g) of the Federal Food, Drug, and Cosmetic Act (the act).

Failure to comply with any postapproval requirement constitutes a ground for withdrawal of approval of a PMA. Commercial distribution of a device that is not in compliance with these conditions is a violation of the act.

You are reminded that, as soon as possible and before commercial distribution of your device, you must submit an amendment to this PMA submission with copies of all approved labeling in final printed form. The labeling will not routinely be reviewed by FDA staff when PMA applicants include with their submission of the final printed labeling a cover letter stating that the final printed labeling is identical to the labeling approved in draft form. If the final printed labeling is not identical, any changes from the final draft labeling should be highlighted and explained in the amendment.

All required documents should be submitted in triplicate, unless otherwise specified, to the address below and should reference, the above PMA number to facilitate processing.

PMA Document Mail Center (HFZ-401)
Center for Devices and Radiological Health
Food and Drug Administration
9200 Corporate Blvd.
Rockville, Maryland 208 50

If you have any questions concerning this approval order, please contact Kesia Alexander, Ph.D. 301-594-2053.

      Sincerely yours,

David M. Whipple
Acting Director
Division of Ophthalmic and Ear,

Nose and Throat Devices

Office of Device Evaluation
Center for Devices and

Radiological Health

Enclosure

3

Last Modified: 1-31-02

CONDITIONS OF APPROVAL

PREMARKET APPROVAL APPLICATION (PMA) SUPPLEMENT. Before making any change affecting the safety or effectiveness of the device, submit a PMA supplement for review and approval by FDA unless the change is of a type for which a “Special PMA Supplement-Changes Being Effected” is permitted under 21 CFR 814.39(d) or an alternate submission is permitted in accordance with 21 CFR 814.39(e) or (f). A PMA supplement or alternate submission shall comply with applicable requirements under 21 CFR 814.39 of the final rule for Premarket Approval of Medical Devices.

All situations that require a PMA supplement cannot be briefly summarized; therefore, please consult the PMA regulation for further guidance. The guidance provided below is only for several key instances.

A PMA supplement must be submitted when unanticipated adverse effects, increases in the incidence of anticipated adverse effects, or device failures necessitate a labeling, manufacturing, or device modification.

A PMA supplement must be submitted if the device is to be modified and the modified device should be subjected to animal or laboratory or clinical testing designed to determine if the modified device remains safe and effective.

A “Special PMA Supplement — Changes Being Effected" is limited to the labeling, quality control and manufacturing process changes specified under 21 CFR 814.39(d)(2). It allows for the addition of, bur not the replacement of previously approved, quality control specifications and test methods. These changes may be implemented before FDA approval upon acknowledgment by FDA that the submission i s being processed as a “Special PMA Supplement — Changes Being Effected.” This procedure is not applicable to changes in device design, composition, specifications, circuitry, software or energy source.

Alternate submissions permitted under 21 CFR 814.39(e) apply to changes that otherwise require approval of a PMA supplement before implementation of the change and include the use of a 30-day PMA supplement or annual postapproval report (see below). FDA must have previously indicated in an advisory opinion to the affected industry or in correspondence with the applicant that the alternate submission is permitted for the change. Before such can occur, FDA and the PMA applicant(s) involved must agree upon any needed testing protocol, test results, reporting format, information to be reported, and the alternate submission to be used.

Alternate submissions permitted under 21 CFR 814.39(f) for manufacturing process changes include the use of a 30-day Notice. The manufacturer may distribute the device 30 days after the date on which the FDA receives the 30-day Notice, unless the FDA notifies the applicant within 30 days from receipt of the notice that the notice is not adequate.

page 1

4

POSTAPPROVAL REPORTS. Continued approval of this PMA is contingent upon the submission of postapproval reports required under 21 CFR 814.84 at intervals of 1 year from the date of approval of the original PMA. Postapproval reports for supplements approved under the original PMA, if applicable, are to be included in the next and subsequent annual reports fox the original PMA unless specified otherwise in the approval order for the PMA supplement. Two copies identified as “Annual Report" and bearing the applicable PMA reference number are to be submitted to the PMA Document Mail Center (HFZ-401), Center for Devices and Radiological Health, Food and Drug Administration, 9200 Corporate Blvd., Rockville, Maryland 20850. The postapproval report shall indicate the beginning and ending date of the period covered by the report and shall include the following information required by 21 CFR 814.84:

  1.   Identification of changes described in 21 CFR 814.39(a) and changes required to be reported to FDA under 21 CFR 814.39(b).

  2.   Bibliography and summary of the following information not previously submitted as part of the PMA and that is known to or reasonably should be known to the applicant:

  a.   unpublished reports of data from any clinical investigations or nonclinical laboratory studies involving the device or related devices (“related” devices include devices which are the same or substantially similar to the applicant’s device); and

  b.   reports in the scientific literature concerning the device.

If, after reviewing the bibliography and summary, FDA concludes that agency review of one or more of the above reports is required, the applicant shall submit two copies of each identified report when so notified by FDA.

ADVERSE REACTION AND DEVICE DEFECT REPORTING. As provided by 21 CFR 814.82(a)(9), FDA has determined that in order to provide continued reasonable assurance of the safety and effectiveness of the device, the applicant shall submit 3 copies a written report identified, as applicable, as an “Adverse Reaction Report” or “Device Defect Report” to the PMA Document Mail Center (HFZ-401), Center for Devices and Radiological Health, Food and Drug Administration, 9200 Corporate Blvd. , Rockville, Maryland 20850 within 10 days after the applicant receives or has knowledge of information concerning:

  1.   A mix-up of the device or its labeling with another article.

  2.   Any adverse reaction, side effect, injury, toxicity, or sensitivity reaction that is attributable to the device and;

  a.   has not been addressed by the device’s labeling; or

  b.   has been addressed by the device’s labeling but is occurring with unexpected severity or frequency.

page 2

      3.

5

Any significant chemical, physical or other change or deterioration in the device, or any failure of the device to meet the specifications established in the approved PMA that could not cause or contribute to death or serious injury but are not correctable by adjustments or other maintenance procedures described in the approved labeling. The report shall include a discussion of the applicant’s assessment of the change, deterioration or failure and any proposed or implemented corrective action by the applicant. When such events are correctable by adjustments or other maintenance procedures described in the approved labeling, all such events known to the applicant shall be included in the Annual Report described under “Postapproval Reports” above unless specified otherwise in the conditions of approval to this PMA. This postapproval report shall appropriately categorize these events and include the number of reported and otherwise known instances of each category during the reporting period. Additional information regarding the events discussed above shall be submitted by the applicant when determined by FDA to be necessary to provide continued reasonable assurance of the safety and effectiveness of the device for its intended use.

REPORTING UNDER THE MEDICAL DEVICE REPORTING (MDR) REGULATION. The Medical Device Reporting (MDR) Regulation became effective on December 13, 1984.This regulation was replaced by the reporting requirements of the Safe Medical Devices Act of 1990 which became effective July 31, 1996 and requires that all manufacturers and importers of medical devices, including in vitro diagnostic devices, report to the FDA whenever they receive or otherwise become aware of information, from any source, that reasonably suggests that a device marketed by the manufacturer or importer:

  1.   May have caused or contributed to a death or serious injury; or

  2.   Has malfunctioned and such device or similar device marketed by the manufacturer or importer would be likely to cause or contribute to a death or serious injury if the malfunction were to recur.

The same events subject to reporting under the MDR Regulation may also be subject to the above “Adverse Reaction and Device Defect Reporting” requirements in the “Conditions of Approval” for this PMA. FDA has determined that such duplicative reporting is unnecessary. Whenever an event involving a device is subject to reporting under both the MDR Regulation and the “Conditions of Approval” for a PMA, the manufacturer shall submit the appropriate reports required by the MDR Regulation within the time frames as identified in 21 CFR 803.10(c) using FDA Form 3500A, i.e., 30 days after becoming aware of a reportable death, serious injury, or malfunction as described in 21 CFR 803.50 and 21 CFR 803.52 and 5 days after becoming aware that a reportable MDR event requires remedial action to prevent an unreasonable risk of substantial harm to the public health. The manufacturer is responsible for submitting a baseline report on FDA Form 3417 for a device when the device model is first reported under 21 CFR 803.50.This baseline report is to include the PMA reference number. Any written report and its envelope is to be specifically identified, e.g., “Manufacturer Report,” “5-Day Report,” “Baseline Report,” etc.

page 3

6

Any written report is to be submitted to:

Food and Drug Administration

Center for Devices and Radiological Health

Medical Device Reporting

PO Box 3002

Rockville, Maryland 20847-3002

Copies of the MDR Regulation (FOD # 336&1336)and FDA publications entitled “An Overview of the Medical Device Reporting Regulation” (FOD # 509) and “Medical Device Reporting for Manufacturers” (FOD #987) are available on the CDRH WWW Home Page. They are also available through CDRH’s Fact-On-Demand (F-O-D) at 800-899-0381.Written requests for information can be made by sending a facsimile to CDRH’s Division of Small Manufacturers International and Consumer Assistance (DSMICA) at 301-443-8818.

page 4

7 -----END PRIVACY-ENHANCED MESSAGE-----